Glass insulator——U160BP

OUR PRODUCTS

Recognized globally, we hold prestigious international certifications including ISO, CE, KEMA, and CESI, ensuring uncompromising quality and reliability worldwide.

GLASS INSULATOR U160BP

The KZAN U160BP is a 160 kN anti-pollution cap-and-pin toughened glass suspension insulator built to IEC 60305. With a nominal structure height of 155 mm, a nominal diameter of 280 mm, and an extended creepage distance of 450 mm, it is engineered for 220 kV to 500 kV overhead transmission lines in heavy pollution areas. Its toughened glass shed features visible self-breakage for fast on-site fault detection, and it is fully interchangeable with standard ball-and-socket fittings as a direct replacement for legacy glass and porcelain strings.

Phone 86-19886663636
Whatsapp 86-19886663636

Details & Specifications

With stable chemical properties and anti-aging characteristics, glass insulators ensure safe power transmission, reduce operational risks, and provide long-term, reliable service for power infrastructure.

Key Features

  • Anti-pollution profile with extended creepage distance for heavy pollution areas.
  • High mechanical strength and thermal stability.
  • Excellent dielectric properties.
  • Visible self-breakage enables fast on-site fault detection without system outage.

Technical Specifications

Project Parameter Values
PRODUCT MODELU160BP/155t
Nominal Diameter D (mm)280
Nominal Structure Height H (mm)155
Nominal Creepage Distance (mm)450t
Socket Coupling Size (mm)16
Mechanical Failing Load (kN)160
Mechanical Routine Test Load (kN)80
Wet Power Frequency Withstand Voltage (kV)45
Dry Lightning Impulse Withstand Voltage (kV)110
Impulse Puncture Voltage (kV)2.8
Power Frequency Puncture Voltage (kV)130
Radio Interference Voltage (μV)≤ 50
Visible Corona Voltage (kV)18/22
Power Frequency Arc Test (s/kA)0.12s/20kA

Applications

  • 220 kV–500 kV AC overhead transmission and distribution lines
  • Heavy pollution areas such as industrial zones, coastal regions and desert environments
  • Substation busbar and tension string installations
  • New-build projects and retrofit of existing insulator strings in polluted conditions

Standards & Compliance

All KZAN U160BP insulators are manufactured and tested in accordance with IEC 60305 and IEC 61109, and verified by third-party laboratories including KEMA and CESI. The anti-pollution profile with extended creepage distance meets the demands of heavy pollution zones. Routine and type tests cover mechanical failing load, electrical withstand voltage, and puncture performance to ensure reliable field operation.

Frequently Asked Questions

What does the 'U160BP' designation mean?

In IEC nomenclature, 'U' denotes a cap-and-pin suspension insulator, '160' is the nominal mechanical failing load of 160 kN, 'B' indicates a ball-and-socket coupling, and 'P' stands for anti-pollution (extended creepage profile). The U160BP is therefore a 160 kN anti-pollution ball-socket glass suspension insulator.

What is the difference between standard and anti-pollution (BP) insulators?

Anti-pollution types have a larger diameter and an extended creepage distance (450 mm versus roughly 320 mm on standard units) to resist pollution flashover in dirty, humid or coastal environments.

Can U160BP glass insulators replace existing porcelain strings?

Yes. They use standard ball-and-socket fittings and are fully interchangeable with legacy glass and porcelain strings in both new-build and retrofit projects.

Which voltage levels are U160BP insulators suitable for?

They are engineered for 220 kV to 500 kV overhead transmission lines in heavy pollution areas.

What standards and certifications apply?

Manufactured and tested to IEC 60305 and IEC 61109, with routine and type tests verified by third-party laboratories including KEMA and CESI. The plant also holds ISO 9001, CE and other international certifications.